Año
Volume shrinkage of bone, brain and muscle tissue in sample preparation for micro-CT and light sheet fluorescence microscopy (LSFM)
J Buytaert, J Goyens, D De Greef, P Aerts, J Dirckx
Microscopy and microanalysis 20 (4), 1208-1217, 2014
1612014
Full-field thickness distribution of human tympanic membrane obtained with optical coherence tomography
S Van der Jeught, JJJ Dirckx, JRM Aerts, A Bradu, AG Podoleanu, ...
Journal of the Association for Research in Otolaryngology 14, 483-494, 2013
1572013
Industrial computer tomography for dimensional metrology: Overview of influence factors and improvement strategies
F Welkenhuyzen, K Kiekens, M Pierlet, W Dewulf, P Bleys, JP Kruth, ...
Proceedings of the 4th international conference on optical measurement …, 2009
862009
Design and quantitative resolution measurements of an optical virtual sectioning three-dimensional imaging technique for biomedical specimens,<? xpp qa?> featuring two …
JAN Buytaert, JJJ Dirckx
Journal of biomedical optics 12 (1), 014039-014039-13, 2007
832007
Moiré profilometry using liquid crystals for projection and demodulation
JAN Buytaert, JJJ Dirckx
Optics Express 16 (1), 179-193, 2008
772008
Details of human middle ear morphology based on micro‐CT imaging of phosphotungstic acid stained samples
D De Greef, JAN Buytaert, JRM Aerts, L Van Hoorebeke, M Dierick, ...
Journal of morphology 276 (9), 1025-1046, 2015
742015
Realistic 3D computer model of the gerbil middle ear, featuring accurate morphology of bone and soft tissue structures
JAN Buytaert, WHM Salih, M Dierick, P Jacobs, JJJ Dirckx
Journal of the Association for Research in Otolaryngology 12, 681-696, 2011
682011
Comparison of the accuracy of digital stereophotogrammetry and projection moiré profilometry for three-dimensional imaging of the face
A Artopoulos, JAN Buytaert, JJJ Dirckx, TJ Coward
International journal of oral and maxillofacial surgery 43 (5), 654-662, 2014
472014
Morphology and function of Bast’s valve: additional insight in its functioning using 3D-reconstruction
R Hofman, JM Segenhout, JAN Buytaert, JJJ Dirckx, HP Wit
European archives of oto-rhino-laryngology 265, 153-157, 2008
452008
MicroCT versus sTSLIM 3D imaging of the mouse cochlea
JAN Buytaert, SB Johnson, M Dierick, WHM Salih, PA Santi
Journal of Histochemistry & Cytochemistry 61 (5), 382-395, 2013
442013
Open access high-resolution 3D morphology models of cat, gerbil, rabbit, rat and human ossicular chains
WHM Salih, JAN Buytaert, JRM Aerts, P Vanderniepen, M Dierick, ...
Hearing Research 284 (1-2), 1-5, 2012
432012
Design considerations in projection phase-shift moiré topography based on theoretical analysis of fringe formation
JAN Buytaert, JJJ Dirckx
JOSA A 24 (7), 2003-2013, 2007
422007
MicroFilament Analyzer, an image analysis tool for quantifying fibrillar orientation, reveals changes in microtubule organization during gravitropism
E Jacques, J Buytaert, DM Wells, M Lewandowski, MJ Bennett, J Dirckx, ...
The Plant Journal 74 (6), 1045-1058, 2013
402013
Insights in the physiology of the human mastoid: message to the surgeon
B Ars, J Dirckx, N Ars-Piret, J Buytaert
The Journal of International Advanced Otology 8 (2), 296, 2012
402012
Real-time geometric lens distortion correction using a graphics processing unit
S Van der Jeught, JAN Buytaert, JJJ Dirckx
Optical Engineering 51 (2), 027002-027002, 2012
392012
Quasi-static transfer function of the rabbit middle ear ‚measured with a heterodyne interferometer with high-resolution position decoder
JJJ Dirckx, JAN Buytaert, WF Decraemer
Journal of the Association for Research in Otolaryngology 7, 339-351, 2006
392006
Phase-shifting Moiré topography using optical demodulation on liquid crystal matrices
JAN Buytaert, JJJ Dirckx
Optics and Lasers in Engineering 48 (2), 172-181, 2010
362010
Assessing urban habitat quality using spectral characteristics of Tilia leaves
ARK Zadeh, F Veroustraete, JAN Buytaert, J Dirckx, R Samson
Environmental Pollution 178, 7-14, 2013
352013
Tomographic imaging of macroscopic biomedical objects in high resolution and three dimensions using orthogonal-plane fluorescence optical sectioning
JAN Buytaert, JJJ Dirckx
Applied optics 48 (5), 941-948, 2009
342009
Leaf injury symptoms of Tilia sp. as an indicator of urban habitat quality
AR Khavaninzadeh, F Veroustraete, JAN Buytaert, R Samson
Ecological indicators 41, 58-64, 2014
332014