Follow
Brian H Brown
Brian H Brown
Verified email at sheffield.ac.uk
Title
Cited by
Cited by
Year
Applied potential tomography
DC Barber, BH Brown
Journal of Physics E: Scientific Instruments 17 (9), 723, 1984
11881984
Electrical impedance tomography (EIT): a review
BH Brown
Journal of medical engineering & technology 27 (3), 97-108, 2003
7612003
GREIT: a unified approach to 2D linear EIT reconstruction of lung images
A Adler, JH Arnold, R Bayford, A Borsic, B Brown, P Dixon, TJC Faes, ...
Physiological measurement 30 (6), S35, 2009
7072009
The Sheffield data collection system
BH Brown, AD Seagar
Clinical physics and physiological measurement 8 (4A), 91, 1987
5211987
Three-dimensional electrical impedance tomography
P Metherall, DC Barber, RH Smallwood, BH Brown
Nature 380 (6574), 509-512, 1996
5181996
Applied potential tomography: possible clinical applications
BH Brown, DC Barber, AD Seagar
Clinical Physics and Physiological Measurement 6 (2), 109, 1985
4081985
Imaging spatial distributions of resistivity using applied potential tomography—APT
DC Barber, BH Brown, IL Freeston
Information Processing in Medical Imaging: Proceedings of the 8th conference …, 1984
3971984
Imaging with electricity: report of the European concerted action on impedance tomography
K Boone, D Barber, B Brown
Journal of medical engineering & technology 21 (6), 201-232, 1997
3141997
Medical physics and biomedical engineering
BH Brown, RH Smallwood, DC Barber, PV Lawford, DR Hose
CRC Press, 2017
2812017
Bipolar electrosurgical scissors
Z Falkenstein, B Brown, JR Brustad
US Patent 7,419,490, 2008
2662008
Relation between tissue structure and imposed electrical current flow in cervical neoplasia
BH Brown, JA Tidy, K Boston, AD Blackett, RH Smallwood, F Sharp
The Lancet 355 (9207), 892-895, 2000
2662000
Whither lung EIT: where are we, where do we want to go and what do we need to get there?
A Adler, MB Amato, JH Arnold, R Bayford, M Bodenstein, SH Böhm, ...
Physiological measurement 33 (5), 679, 2012
2092012
Medical impedance tomography and process impedance tomography: a brief review
BH Brown
Measurement Science and Technology 12 (8), 991, 2001
2052001
Applications of applied potential tomography (APT) in respiratory medicine
ND Harris, AJ Suggett, DC Barber, BH Brown
Clinical Physics and Physiological Measurement 8 (4A), 155, 1987
1951987
Mk3. 5: a modular, multi-frequency successor to the Mk3a EIS/EIT system
AJ Wilson, P Milnes, AR Waterworth, RH Smallwood, BH Brown
Physiological Measurement 22 (1), 49, 2001
1942001
Recent developments in applied potential tomography-APT
DC Barber, BH Brown
Information Processing in Medical Imaging: Proceedings of the 9th conference …, 1986
1871986
Theoretical limits to sensitivity and resolution in impedance imaging
AD Seagar, DC Barber, BH Brown
Clinical Physics and Physiological Measurement 8 (4A), 13, 1987
1841987
A real-time electrical impedance tomography system for clinical use-design and preliminary results
RWM Smith, IL Freeston, BH Brown
IEEE Transactions on Biomedical Engineering 42 (2), 133-140, 1995
1821995
Intestinal smooth muscle electrical potentials recorded from surface electrodes
BH Brown, RH Smallwood, HL Duthie, CJ Stoddard
Medical and biological engineering 13, 97-103, 1975
1671975
Cardiac and respiratory related electrical impedance changes in the human thorax
BH Brown, DC Barber, AH Morice, AD Leathard
IEEE Transactions on Biomedical Engineering 41 (8), 729-734, 1994
1651994
The system can't perform the operation now. Try again later.
Articles 1–20