A review of sprinkler system effectiveness studies
K Frank, N Gravestock, M Spearpoint, C Fleischmann
Fire science reviews 2, 1-19, 2013
662013
B-RISK user guide and technical manual
CA Wade, GB Baker, K Frank, AP Robbins, R Harrison, M Spearpoint, ...
BRANZ, 2013
592013
B-RISK 2016 user guide and technical manual
CA Wade, GB Baker, K Frank, R Harrison, M Spearpoint
BRANZ, 2016
262016
Uncertainty in estimating the fire control effectiveness of sprinklers from New Zealand fire incident reports
K Frank, M Spearpoint, N Challands
Fire technology 50, 611-632, 2014
252014
A comparison of a priori modelling predictions with experimental results to validate a design fire generator submodel
G Baker, P Collier, C Wade, M Spearpoint, CM Fleischmann, K Frank, ...
Proceedings of Fire and Materials, 449-460, 2013
192013
Façade Fire Incidents in Tall Buildings.
M Spearpoint, I Fu, K Frank
CTBUH Journal, 2019
102019
Finding the probability of doors being open using a continuous position logger
K Frank, M Spearpoint, S Weddell
Fire Safety Science 11, 969-982, 2014
82014
Fire safety system effectiveness for a risk-informed design tool
KM Frank
University of Canterbury. Civil and Natural Resource Engineering, 2013
82013
A comparison of sources of uncertainty for calculating sprinkler activation
K Frank, M Spearpoint, CM Fleischmann, C Wade
Fire Safety Science 10, 1101-1114, 2011
82011
Large eddy simulation of room fire spread using a medium scale compartment made of medium density fibreboard (MDF) panels
J Baolati, K Li, Y Zou, K Frank, G Hare, J Zhang, F Ge
Building Simulation 15 (4), 495-510, 2022
72022
Modelling the activation of multiple sprinklers with a risk-informed design tool
K Frank, MJ Spearpoint, CM Fleischmann, CA Wade
9th International Conference on Performance-Based Codes and Fire Safety Design, 2012
62012
Measuring modified glass bulb sprinkler thermal response in plunge and compartment fire experiments
K Frank, M Spearpoint, G Baker, C Wade, P Collier, C Fleischmann
Fire safety journal 91, 662-670, 2017
42017
Fire resistance requirements in single-storey industrial and warehouse buildings
CA Wade, K Frank
BRANZ, 2019
32019
The impact of user decision-making in the application of computational compartment fire models
G Baker, M Spearpoint, K Frank, C Wade, S Sazegara
Fire safety journal 91, 964-972, 2017
32017
The next generation of performance-based fire safety engineering in New Zealand
G Baker, K Frank, M Spearpoint, C Fleischmann, C Wade
University of Canterbury. Civil and Natural Resources Engineering, 2013
32013
Flammability tests for building facades
E Soja, C Wade, K Frank
Flammability Testing of Materials Used in Construction, Transport and Mining …, 2022
22022
Fuel tank and charcoal canister fire hazards during EVAP system leak testing
K Frank, D Checkel
SAE Technical Paper, 2007
22007
Flammability hazards of fuel system leak testing
KM Frank
22006
Reaction-to-Fire Behaviour of Partial Quantities of Timber Surface Linings in Compartments
GB Baker, CA Wade, K Frank
Research and Advanced Technology in Fire Safety. Ed. by D. Alvear. Santander …, 2017
12017
Effects of deflector slot/tine ratio on sprinkler spray uniformity using 3D printing technology
T Yang, K Frank, J Tu, Y Li, Q Chen, K Li
Fire safety journal 134, 103700, 2022
2022