Seguir
Niccolo Fuin
Niccolo Fuin
Research Associate, King's College London
Dirección de correo verificada de kcl.ac.uk
Título
Citado por
Citado por
Año
CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions
T Küstner, N Fuin, K Hammernik, A Bustin, H Qi, R Hajhosseiny, PG Masci, ...
Scientific reports 10 (1), 13710, 2020
1732020
From compressed-sensing to artificial intelligence-based cardiac MRI reconstruction
A Bustin, N Fuin, RM Botnar, C Prieto
Frontiers in cardiovascular medicine 7, 17, 2020
1142020
Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast
OA Catalano, D Daye, A Signore, C Iannace, M Vangel, A Luongo, ...
International journal of oncology 51 (1), 281-288, 2017
592017
Magnetic resonance fingerprinting using recurrent neural networks
I Oksuz, G Cruz, J Clough, A Bustin, N Fuin, RM Botnar, C Prieto, AP King, ...
2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019 …, 2019
432019
Deep‐learning based super‐resolution for 3D isotropic coronary MR angiography in less than a minute
T Küstner, C Munoz, A Psenicny, A Bustin, N Fuin, H Qi, R Neji, K Kunze, ...
Magnetic Resonance in Medicine 86 (5), 2837-2852, 2021
402021
A multi-scale variational neural network for accelerating motion-compensated whole-heart 3D coronary MR angiography
N Fuin, A Bustin, T Küstner, I Oksuz, J Clough, AP King, JA Schnabel, ...
Magnetic resonance imaging 70, 155-167, 2020
402020
Non-rigid respiratory motion estimation of whole-heart coronary MR images using unsupervised deep learning
H Qi, N Fuin, G Cruz, J Pan, T Kuestner, A Bustin, RM Botnar, C Prieto
IEEE Transactions on Medical Imaging 40 (1), 444-454, 2020
362020
PET/MRI in the presence of metal implants: completion of the attenuation map from PET emission data
N Fuin, S Pedemonte, OA Catalano, D Izquierdo-Garcia, A Soricelli, ...
Journal of Nuclear Medicine 58 (5), 840-845, 2017
342017
Concurrent respiratory motion correction of abdominal PET and dynamic contrast-enhanced–MRI using a compressed sensing approach
N Fuin, OA Catalano, M Scipioni, LPW Canjels, D Izquierdo-Garcia, ...
Journal of Nuclear Medicine 59 (9), 1474-1479, 2018
312018
Comparison of the clinical performance of upper abdominal PET/DCE-MRI with and without concurrent respiratory motion correction (MoCo)
OA Catalano, L Umutlu, N Fuin, ML Hibert, M Scipioni, S Pedemonte, ...
European Journal of Nuclear Medicine and Molecular Imaging 45, 2147-2154, 2018
262018
Transmission imaging for integrated PET-MR systems
SL Bowen, N Fuin, MA Levine, C Catana
Physics in Medicine & Biology 61 (15), 5547, 2016
192016
Efficient determination of the uncertainty for the optimization of SPECT system design: A subsampled Fisher information matrix
N Fuin, S Pedemonte, S Arridge, S Ourselin, BF Hutton
IEEE transactions on medical imaging 33 (3), 618-635, 2013
122013
A variational neural network for accelerating free-breathing whole-heart coronary MR angiography
N Fuin, A Bustin, T Kuestner, R Botnar, C Prieto
Proceedings of the International Society of Magnetic Resonance in Medicine, 9-12, 2019
92019
Accelerating 3D MTC-BOOST in patients with congenital heart disease using a joint multi-scale variational neural network reconstruction
A Fotaki, N Fuin, G Nordio, CV Jimeno, H Qi, Y Emmanuel, K Pushparajah, ...
Magnetic Resonance Imaging 92, 120-132, 2022
72022
Variance prediction in SPECT reconstruction based on the fisher information using a novel angular blurring algorithm for computation of the system matrix
A Bousse, K Erlandsson, N Fuin, D Salvado, BF Hutton
2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS …, 2013
62013
Collimator design in SPECT, an optimisation tool
N Fuin, A Bousse, S Pedemonte, S Arridge, S Ourselin, B Hutton
IEEE Nuclear Science Symposuim & Medical Imaging Conference, 3149-3154, 2010
62010
CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions. Sci Rep 2020; 10: 13710
T Küstner, N Fuin, K Hammernik, A Bustin, H Qi, R Hajhosseiny
Epub 2020/08/15.[Europe PMC free article][Abstract][Google Scholar], 0
5
Accelerated 4D respiratory motion-resolved cardiac MRI with a model-based variational network
H Qi, N Fuin, T Kuestner, R Botnar, C Prieto
Medical Image Computing and Computer Assisted Intervention–MICCAI 2020: 23rd …, 2020
22020
Use of the Fisher Information Matrix to optimize the acquisition protocol for a D-SPECT system
N Fuin, S Pedemonte, S Arridge, S Ourselin, BF Hutton
2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record …, 2012
22012
Subsampled Fisher Information Matrix for efficient estimation of the uncertainty in emission tomography
N Fuin, S Pedemonte, S Arridge, S Ourselin, BF Hutton
2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record …, 2012
22012
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20